Search results for "Flat panel detector"

showing 2 items of 2 documents

Radiation exposure in biliary procedures performed to manage anastomotic strictures in pediatric liver transplant recipients: comparison between radi…

2013

The aim of this study was to estimate radiation exposure in pediatric liver transplants recipients who underwent biliary interventional procedures and to compare radiation exposure levels between biliary interventional procedures performed using an image intensifier-based angiographic system (IIDS) and a flat panel detector-based interventional system (FPDS). We enrolled 34 consecutive pediatric liver transplant recipients with biliary strictures between January 2008 and March 2013 with a total of 170 image-guided procedures. The dose-area product (DAP) and fluoroscopy time was recorded for each procedure. The mean age was 61 months (range 4–192), and mean weight was 17 kg (range 4–41). The…

Malemedicine.medical_specialtyAdolescentmedicine.medical_treatmentConstriction PathologicAnastomosisPercutaneous transhepatic cholangiographyRadiation DosageRadiography InterventionalPediatricsFlat panel detectorlaw.inventionCatheterizationCholangiographyArteriovenous Shunt SurgicallawmedicineFluoroscopyHumansRadiology Nuclear Medicine and imagingChildPediatric Liver Transplantmedicine.diagnostic_testbusiness.industryUltrasoundImage intensifierRadiation ExposureLiver TransplantationRadiation exposureRadiographic Image EnhancementChild PreschoolFluoroscopyFemaleRadiologyCardiology and Cardiovascular MedicinebusinessAngioplasty BalloonCholangiographyCardiovascular and interventional radiology
researchProduct

Experimentelle In-vitro-Studie zur Evaluierung eines elektronischen Detektors für die digitale Radiographie

2004

Purpose: To evaluate the contrast-detail performance of a flat-panel detector system, we performed a comparative study of this flat-panel system versus storage phosphor and conventional screen-film systems. Materials and Methods: Bone models made of human humeri were prepared with foreign bodies, fracture lines and drilled holes to create artificial fractures, osteolyses or metastases. Immersed in a water bath, hard copy images of these models were acquired with the same exposure dose (55 kV; 3.2 mAs) on the flat-panel detector, two state-of-the-art storage phosphor systems (PCR®, ADC®) and two conventional screen-film systems (Insight®, T-Mat®). Using a standardized protocol with a 4-point…

Materials sciencebusiness.industryRadiographyStorage phosphorDetectorRadiology Nuclear Medicine and imagingRadiographic Image EnhancementNuclear medicinebusinessForeign BodiesImaging phantomFlat panel detectorDigital radiographyRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct